Grupo Industronic
UPS UPS-IND 1300, NO BREAK
movil08
Industrial UPS with surge protection for use in industrial units, machinery, robotics and commercial buildings
UPS UPS-IND 1300, NO BREAK
1300_slide
Industrial UPS with surge protection for use in industrial units, machinery, robotics and commercial buildings

VIDEO

Features

CARACT_UPS_1300

Features

  • Online double conversion, enabling continuous operation of electrical equipment
  • Full DSP control provides high reliability and performance
  • Advanced power factor correction technology
  • Cold-start capability, battery cold-start

Technical Specifications

  • Voltage Range
    120/220 +/- 25%
  • Output Voltage Options
    120/220 +/- 1%
  • Power Factor
    80%
  • Efficiency
    99%
  • Isolation Transformer
    220V input and 120/208/220/240V +/- 1% output
  • Smart Communications Port
    RS-232/RS-485
  • Output Distortion
    Less than 3% THD (linear load)
  • Overload protection
    Circuit breaker switch at the input terminal
  • Backup
    7 min. at 100% load, 18 min. at 50% load
  • Output Operating Frequency
    50 or 60Hz +/- 0.2% (battery mode)
  • Interface
    RS-232 Smart UPS (optional SNMP interface)
  • Configuration
    Tower
  • Alarm Type
    Audible

Supplemental Options

  • External SNMP adaptor
  • Technology for parallel capacity or redundancy
  • External battery bank for extended backup time
  • Smart battery monitoring system
  • Industronic Power Conditioner/Voltage Regulator to protect the UPS and extend battery life

UPS-IND Illustration

  1. Display
  2. Control Panel
  3. Maintenance Bypass
  4. SNMP Card
  5. Output switch
  6. Intput switch
  1. Battery switch
  2. Bypass switch
  3. Intput & Output power connection
  4. Batteries
  5. Emergency stop button
ups13004

SPECIFICATION TABLE

INPUT

MODEL 1346 1350 1353 1358 1362 1366 1370 1376 1378
Capacity (kW / kVA) 8/10 12/15 16/20 24/30 32/40 40/50 48/60 64/80 80/100
Overloading protection Input Thermal-magnetic breaker and bypass
Voltage (VAC) 120 / 208, 127 / 220 or 277 / 480 ± 20% to 100%, ± 25% to 75% load, and ± 30% to 50% load
Phases 3 phases (4 wires + ground)
Frecuency (Hz) 60 ± 10% (50 ± 10% optional)
Input power factor 0.80 empty, > 0.95 at full load
Overloading protection Output Thermal-magnetic breaker

 

OUTPUT

MODEL 1346 1350 1353 1358 1362 1366 1370 1376 1378
Output power factor 0.8
Voltage (VAC) 120 / 208, 127 / 220 or 277 / 480 ± 1%, typical (3 phases, 4 wires + ground)
Frecuency (Hz) 60 ± 0.2% (50 ± 0.2% optional)
Waveform Pure sine wave THD ≤ 3% (lineal load)
Transfer Time (ms) 0.0 (online)
Connection type Estrella
Overload 130% load for 60 seconds.; 150% for 10 seg

 

BATTERIES

MODEL 1346 1350 1353 1358 1362 1366 1370 1376 1378
Voltage (Vcd) 192 348 348 – 360 (adjustable)
Battery type Sealed and free maintenance lead acid
Maximum Load Current (A) (min) 5
Current of maximum load (A) 4 6 10
Battery pack Intern * Externo
Dimensions (width × depth × height in cm)** Intern 43 x 120 x 160 90x80x190
Batteries bank weight (kg)** Intern 374 382 616 761 992

 

PHYSICAL AND MECHANICAL

MODEL 1346 1350 1353 1358 1362 1366 1370 1376 1378
Acoustical noise (dB) < 65, to 3 feet
MTBF (hrs) 233,000
Operating temperature (°C) 0 – 40
Relative humidity 0 ~ 95% without condensation
Maximum operating elevation (FASL) 2,000 to 100% & 3,000 to 96%
Cabinet Steel with electrostatic epoxy paint
Dimensions (width × depth × height in cm)** 50 x 80 x 170 80 x 80 x 162 140 x 80 x 180
UPS weight (kg)** 390 410 440 470 590 620 670 965 1000

 

TECNOLOGY

MODEL 1346 1350 1353 1358 1362 1366 1370 1376 1378
Conversion type Online double conversion
Rectifier SCR type of 6 pulse with phase control
Inverter switch components IGBT Tecnology switched at a rate of 9000 Hz
Batteries state Online Information & real time download with 3% accuracy
Heat dissipation (kBTU/h) 30.33 45.50 60.67 91.01 94.96 118.71 142.45 189.93 237.42
Internal Bypass two bypass: one automatic static & one manual for maintenance
Paralleling in n + 1 to 4 equipments
Certifications CE-IEC 62040 – 1, ISO 9001:2008, NOM
Communications interface RS-232, RS-485, dry-contact relay signal, SNMP/Modbus network card with one equipment port and two parallel ports
Screen (monochromatic LCD) Backlit: input and output voltage; load capacity; battery voltage; operating status; mimic panel
Alarms Irregular main input, low battery voltage and UPS malfunction
Protection Thermal-magnetic circuit breakers at current input and output for battery banks

Due to continuous improvements in our products, specifications are subject to change and change without notice.

Downloads

UPS-IND 1300

Model Data Sheet Manual
UPS1300 (10-30 kVA) Download
UPS1300 (40-60 kVA) Download
UPS1300 (80-400kVA) Download

Power Calculator

Instantly calculate the capacity of the equipment that you require filling the following fields:

CURRENT:

PHASES:

KVAS:

Calculate

Request Pricing

Name*:

E-mail*:

Phone*:

Company:

Country*:

Comments*:

Information about your inquiry:

*Required

logos
Top
INDUSTRONIC INDUSTRONIC
×