Grupo Industronic
UPS-IND 1300 PEMEX
movil10
UPS Pemex con protección contra sobrecargas para aplicaciones como sistema de control distribuido, equipo de análisis y control, laboratorios, equipos de instrumentación, sistema de parada de emergencia, sistemas de gas y fuego.

UPS-IND 1300 PEMEX
1300pmx_slide
Pemex UPS with surge protection for use in laboratories, Distributed control system, control analysis equipment, laboratorios, instrumentation equipment, gas & fire systems.

VIDEO

FEATURES

CARACT_UPS_1300_PXM

FEATURES

  • Online doble conversion
  • High reliability & performance DSP Control
  • Power factor correction
  • Cold-start capability (battert cold-start)
  • Battery power management
  • Smart ventilation
  • MODBUS Card
  • IGBT inverter and isolation transformer at input
  • Maintenance bypass (included)
  • Automatic electronic bypass
  • Automatic safety shut-off at input
  • Industronic Power Conditioner/Voltage Regulator to protect the alternative alimentation line
  • Modulation by wide pulse (6 or 12) PWM
  • External manual diversion commutator
  • More than 20 years of useful life
  • Overload of 150% for 1 min & 125% for 10 min.
  • Cabinet IP21
  • Designed for backing up NiCd batteries

TECHNICAL SPECIFICATIONS

  • Input Voltage Range
    220 or 480 (± 20%) VAC
  • Output Voltage Options
    120, 127, 220 or 480 VAC (± 1%).
  • Power Factor
    0.8 (optional 0.9).
  • Efficiency
    90%
  • Output Distortion
    Less than 3% THD (linear load)
  • Isolation Transformer
    Input: 220 or 480 VAC.
    Output: 120, 127, 220 or 480 VAC.
  • Environmental conditions
    Operation in humid tropical climates and corrosive saline environments; tropicalized bolts (galvanized, chrome-plated) with lock washers
  • Overload Protection
    Thermal-magnetic input breaker
  • Output Operating Frequency
    60 Hz ± 0.2% (optional 50 Hz ± 0.2%)
  • Transfer time
    0.0 ms (online)
  • Interface
    RS-232 and RS-485; UPS smart Modbus card
  • Configuration
    Tower
  • Alarm Type
    Audible

SUPPLEMENTAL OPTIONS

Technology for parallel capacity or redundancy

Smart monitoring system for batteries

UPS Diagram. PWM Technology - PEMEX use

ups1300pemex04

SPECIFICATION TABLE

INTPUT

MODEL UPS-IND 1330 UPS-IND 1346 UPS-IND 1350 UPS-IND 1353 UPS-IND 1358 UPS-IND 1362 UPS-IND 1366
Capacity (kW/kVA) 4/5 8/10 12/15 16/20 24/30 32/40 40/50
Overloading protection Input Thermal-magnetic breaker and bypass
Voltage (VAC) 220 or 480±20%
Phases 3 phases (3 wires + ground)
Frecuency (Hz) 60±10% (50±10% optional)
Power Factor 0.80 empty, > 0.95 full load
Overloading protection Output Thermal-magnetic breaker
Power Factor 0.8 (optional 0.9)

 

OUTPUT

MODEL UPS-IND 1330 UPS-IND 1346 UPS-IND 1350 UPS-IND 1353 UPS-IND 1358 UPS-IND 1362 UPS-IND 1366
Voltage (VAC) 120,127 1 phase (LNT) or 480 3 phases (LLLNT)±1%
Frecuency (Hz) 60 ± 0.2% (50 ± 0.2% optional)
Waveform Pure sine wave THD ≤ 3% (linear load)
Transfer Time (ms) 0.0 (online)
Rim factor 3
Connection type Monofásico ó Trifásico
Overload 125% for 10 min; 150% for 1 min

 

PHYSICAL AND MECHANICAL

MODEL UPS-IND 1330 UPS-IND 1346 UPS-IND 1350 UPS-IND 1353 UPS-IND 1358 UPS-IND 1362 UPS-IND 1366
Acoustical noise (dB) MTBF (hrs), 233000
Operating temperature (°C) (°C) 0 ~ 40
Relative humidity 0 ~ 95% without condensation
Maximum operating elevation (FASL) 2000 at 100% / 3000 at 96%
Cabinet Metallic, steel with electrostatic epoxy paint, for installation indoors, dead-front, self-supporting, IP21, green PEMEX 628
Dimensions (width × depth × height in cm)** 80 x 80 x 180 100 x 80 x 180
UPS weight (kg)** 490 500 540 560 590 690 740

 

BATTERIES

MODEL UPS-IND 1330 UPS-IND 1346 UPS-IND 1350 UPS-IND 1353 UPS-IND 1358 UPS-IND 1362 UPS-IND 1366
Voltage (Vcd) 220
Battery type Nickel-cadmium internal gas recombination
Backup time at full load (min.) 30 (standard)
Maximum load current (A) 20 40 61 81 121 162 202
Battery bank Open, with tiered steel supports, welded, 628 green color for PEMEX for installation indoors (vertical or horizontal layout)
Battery bank dimensions (cm)** According to specifications
Battery bank weight (kg)** According to specifications

 

EXTERN COMMUTATOR

MODEL UPS-IND 1330 UPS-IND 1346 UPS-IND 1350 UPS-IND 1353 UPS-IND 1358 UPS-IND 1362 UPS-IND 1366
Input Voltage (VAC) 120, 127 1 Phase (LNT) or 127/220, 277/480 3 Phases (LLLNT)
Output Voltage (VAC) Reflect input voltage
Overloading capacity 200% for 10 sec
Intput/Output electricity (A) According to specifications
Quality Industrial, commercial y domestic, for indoor use type 1
Cabinet Metallic, steel with electrostatic epoxy paint, for installation indoors, dead-front, self-supporting, IP21, PEMEX 628 green
Dimension of external commutator(cm)** According to specifications
Weight of external commutator (kg)** According to specifications

 

ALTERNATIVE LINE

MODEL UPS-IND 1330 UPS-IND 1346 UPS-IND 1350 UPS-IND 1353 UPS-IND 1358 UPS-IND 1362 UPS-IND 1366
Input Voltage (VAC) 127, 220, or 480 ± 15%
Output Voltage (VAC) 120, 127 1 Phase (LNT) or 220, 480 3 Phases (LLLNT) ± 1%
Input Thermal-magnetic breaker Min 10kA, 22kA y 25kA according to input voltage
Isolation Transformer Copper Dry type
Quality Industrial with protection factor k-13
Cabinet Metallic, steel with electrostatic epoxy paint, for installation indoors, dead-front, self-supporting, IP21, PEMEX 628 green
Regulator Dimensions (cm)** 80 x 80 x 180
Regulator Weight(kg)** 350 380 410 430 480 520 570

 

TECNOLOGY

MODEL UPS-IND 1330 UPS-IND 1346 UPS-IND 1350 UPS-IND 1353 UPS-IND 1358 UPS-IND 1362 UPS-IND 1366
Conversion type nline double conversion, microprocessor-controlled
Rectifier T6- or 12-pulse SCR with phase control
Filters Contraharmonic mean (loop: 2 % RMS)
Isolation transformer Dry-type transformer included at input
Inverter switch components Static with PWM technology and IGBTs switched at 9000 Hzz
Battery status Information online or via real-time download with accuracy of ± 3 %
Heat dissipation (kBTU/h) 1.4 2.7 4.1 5.5 8.2 10.9 13.6
Static switch Static bypass with automatic transfer
Maintenance bypass Manual mechanical bypass
Paralleling in n + 1 up to 4 pieces of equipment
Certifications CE-IEC 62040-1. CE-IEC 62040-2, ISO 9001:2008
Reference regulation NRF-249-PEMEX-2010
Communications interface RS-232, RS-485, dry-contact relay signal, SNMP/Modbus network card with one equipment port and two parallel ports
Screen (LCD touchscreen) Backlit: input and output voltage; load capacity; battery voltage; operating status; mimic panel
Dry contacts Inverter in operation; rectifier, inverter or static switch failure; normal operation; low battery; fan failure; rectifier power supply failure
Alarms Output overload; non-standard AC input; low battery; rectifier or charger failure; inverter failure; no power supply; battery in operation; ground failure; transfer to alternative line; overheating
Protection Thermal-magnetic circuit breakers at current input and for battery banks

**Approximate weight & dimensions without packaging.

Due to continuous improvements in our products, specifications are subject to change and change without notice.

DOWNLOADS

UPS-IND 1300 INDUSTRIAL PEMEX

Model Data Sheet Manual
UPS PEMEX (5-50KVA) Download
UPS PEMEX (60-120KVA) Download
UPS PEMEX (160-400KVA) Download

POWER CALCULATOR

Instantly calculate the capacity of the equipment that you require filling the following fields:

CURRENT:

PHASES:

KVAS:

Calculate

REQUEST PRICING

Name*:

E-mail*:

Phone*:

Company:

Country*:

Comments*:

Information about your inquiry:

*Required

logos
Top