CARACT_G3_6

FEATURES

  • Voltage regulation (+/-2%)
  • 10-year warranty
  • Overload capacity of up to 400% in intermittent surges
  • Critical equipment protection in hostile environments
  • Voltage spike suppressor included
  • Auto shutdown
  • Quiet operation with minimal generation of heat
  • Original patents
  • Average efficiency of 99%

APPLICATIONS

  • Telephone and communications equipment
  • Computer equipment
  • Medical and laboratory equipment
  • Printers and plotters
  • Household appliances
  • Machine tools and numeric control machinery
  • Audiovisual equipment
  • Lighting systems
  • Robotics
  • Automated assembly lines

SUPPLEMENTAL OPTIONS

  • Energy-saving sensor
  • Maintenance bypass
  • Paralleling
  • Input regulation up to +/-45%
  • Custom design
  • Isolation Transformer/Autotransformer

TECHNICAL SPECIFICATIONS

Input Voltage Range
±15%, ±25% or ±45%
Output Voltage Range
±2% or ±5%
Nominal Voltage
From 100 to 600 VAC
Efficiency
99% Average
Overload
Up to 400% in intermittent surges
Operating frequency (Hz)
60 Hz ±10% (50 Hz optional)
Harmonic distortion
Less than 2% THD, does not add harmonic distortion
Power factor
Reflects that of the load
Correction time
Immediate

REGULATION SCHEME

amcr_esquema_n

SPECIFICATION TABLES

PROTECTION MODULE
Against overload and short circuit Circuit breaker switch at the input terminal, fuses according to the model
Against voltage spikes Varistors (voltage spike suppressors) at the output terminal
Against high-frequency noise Pi filter
Against power surges and brownouts Auto shutdown relay at the output terminal, according to the model
Reset Automatic or manual (programmable at the factory)
Reset time 3 seconds standard time*

 

TECHNOLOGY
Monitoring Voltage levels per phase"
Operating status Active or shutdown output (for low or high voltage)
Electronic switches TRIACs

 

PHYSICAL SPECIFICATIONS
Recommended use Industrial, commercial and domestic, for stationary indoor use
Converters Magnet wire made of electrolytic copper and silicon steel sheeting
Cooling and ventilation By natural convection
Cabinet Galvanized steel sheeting on a steel tube base
Finish and paint Main layer covered with glazed epoxy
Connections Clamp connector, wire, pin or outlet power strips

 

INPUT SPECIFICATIONS
Operating frequency 60 Hz ±10%, does not alter the frequency**
Harmonic distortion Less than 2% THD
Power factor Does not alter; reflects that of the load
Source impedance Less than 2%
Operating temperature 0 – 40 ºC (32 – 104°F)
Relative humidity 0 – 95% without condensation
Altitude Maximum of 3000 meters (9842 ft.) above sea level
THREE-PHASE
Model kVAs Volts Height* Width* Depth* Weight**
AMCR G3-2306 6 120/208 ó 277/480 67 28 64  40
AMCR G3-2310 10 120/208 ó 277/480 67 28 64  45
AMCR G3-2315 15 120/208 ó 277/480 67 28 64  54
AMCR G3-2320 20 120/208 ó 277/480 67 28 64  65
AMCR G3-2325 25 120/208 ó 277/480 67 28 64  77
AMCR G3-2330 30 120/208 ó 277/480 67 28 64  86

*Due to continuous improvements in our products , specifications are subject to change and change without notice .

DOWNLOADS

AMCR: REGULATOR / CONDITIONERS

Model Data sheet Manual
AMCR G3 – 2300 Download Download

POWER CALCULATOR

Instantly calculate the capacity of the equipment that you require filling the following fields:

CURRENT:

PHASES:

KVAS:

Calculate

REQUEST PRICING

Name*:

E-mail*:

Phone*:

Company:

Country*:

Comments*:

Information about your inquiry:

*Required

logos
Top
INDUSTRONIC INDUSTRONIC
×